Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsDiesel Generator Set

Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time

Good quality Diesel Engine Water Pump for sales
Good quality Diesel Engine Water Pump for sales
The products are superior in quality and cheap in quality. And the company has a great future!

—— Mr Orlande

I'm Online Chat Now

Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time

China Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time supplier
Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time supplier Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time supplier Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time supplier Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time supplier

Large Image :  Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time

Product Details:

Place of Origin: China
Brand Name: BST
Certification: CE
Model Number: BST-120GT

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: Negotiated Price
Packaging Details: ply-wood case
Delivery Time: 10 work days
Payment Terms: L/C, T/T
Supply Ability: 5000 unit per month
Contact Now
Detailed Product Description
Speed: 1500rpm Frequency: 50HZ
Cylinder: 6 Type: Open Type
Air Inlet: Turbo Intercooled Bore/Trip: 105/130
Engine: R6105IZLD Connecting Type: 3 Phase And 4 Wires

 

 

120KW / 150KVA Water Cool Small Diesel Generator Set 50HZ Diesel Genset Open Type

 

Diesel generator use method and matters needing attention


1.Installation requirements 

Keep the machine room clean.A dry,Inlet and outlet air is clear.The unit must exhaust the air duct hood to prevent hot air from returning to the machine room;Muffler shallMust be properly hoisted,To avoid crushing the supercharger.When used in high dust environment,Not only in the machine room to install filters and dustproofNets keep out excess dust(unit water tank,Premature blockage of air filtration,Measures should also be taken to prevent the dust from entering the exhaust pipe.In the exhaust duct.
 

2.Operation
2.1 Select the oil that meets the requirements of the generator. Before starting the engine, check whether the oil level and cooling level are normalLocation, continuous boot operation4Check the oil level around the hour.
2.2 Choose the antifreeze or antirust solution approved by the manufacturer according to the ambient temperature.Add after adjusting to proportion;Don'tUse clean water only (rusting of engine channel, cavitation erosion, rust of thermostat, etc.).Add cooling fluid to generate electricityThe machine body exhausts air to prevent damage to the cylinder in the channel
2.3 The unit is forbidden to work under overload.The unit is strictly forbidden to be hit by large load.
2.4 Before the unit is shut down, load is discharged and no load is operated3 ~ 5Stop after a minute.The unit is not allowed to operate for a long time under low load or idle state.The spare unit should be operated without load at least once a month.Empty vessels carryingTurn time10to15Minutes;And the annual load (80%At least operation2to4Hours.
2.5 The power supply of the reserve unit should be charged regularly, and the electrolytic level of the battery should be checked at the same time. If not enough, it should be added in time (it can be steamedBoiling water).Check whether the connection of the battery line is firm. Do not connect the wrong way.
2.6 Operating personnel carefully complete the unit's operation, maintenance records.

 

3.Maintenance
3.1 Unit operation 200 to 300 oil must be changed every hour or every year. Oil must be removed at the same time device (including bypass).Oil should be used for the first time or under harsh conditions 100 change within hours.
3.2 The engine's air filter is available 500 change in an hour or two;More dust and other harsh environmental conditions will be greatly reducedThe cycle of empty filter, observe the position indicated by the empty filter blocker, indicate that it must be replaced when entering the red area.
3.3 The coolant is replaced every two years, and the coolant filter should be replaced annually.
3.4 The quality diesel must be chosen in line with national standards.The first care should be cleaned regularly, with fine aluminum for each use 500 hours should be replaced.With oil water separator unit each use50 drain or replace the filter element regularly around the hour.
3.5 Never reuse the engine after cleaning.Select pure engine filters and components.

 

Parameter
 

1. Specification of genset
Gensets model BST-120GF
Prime power 120kw
Rated Voltage 400/230V
Rated frequency(HZ) 50
Rated Speed 1500rpm
Power Factor 0.8(lagging)
Dimensions(mm) (L×W×H) 1850X720X1250mm Open type
Genset Weight(kg) 1000  
2. Specification of diesel engine
Engine brand R6105IZLD
Number of Cylinders 6
Bore×Stroke (mm×mm) 105*135
Cylinder arrangement Vertical in-line
Cycle Four stroke
Aspiration Turbo INtercooled, Air/Water cooling
Cooling System Forced Water Cooling Cycle
3. Specification of alternator
Number of Phase 3
Connecting Type 3 Phase and 4 Wires
Number of Bearing 1
Protection Grade IP23
Altitude ≤1000m
Exciter Type Brushless ,Self-exciting, AVR automatic voltage regulating,
100% Copper winding wire (Brush is also available)
Insulation Class H
Telephone Influence Factor (TIF) ≤50
THF ≤2%
Voltage Regulation, Steady State ≤±1%
Transient State Voltage ≤-15%~+20%

 

Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time
 
Why choose us?


1. Original Factory We Are . we have a large stock and Spare Part Warehouse .
2. 2KW--2000KW diesel engine which used for generator, drainage and irrigation equipment, fire unit,
and the ship.the voltage is 220/380V,230/400V,240/415V or as your request.
3.Top Quality Engine with Famous Brand Alternator(Stanford,Marathon,well-know brands at home and abroad.)
4. With competitive price. More order, more discounts will get !
5. Best after-sales services : whole life technical support and one year warranty time.
6. Fast delivery time : in 10 days after get the deposit.

 

 Water Cool Small 50HZ Diesel Power Generator Set Open Type Long Life Time

 

Our service

1.Pre-service
Our factory provides a full line of brand new and high quality products.Each and every unit is strictly factory tested before shipment.

2.After-service
Once receive any feedback of quality problem we will respond at the first time, and solve the problems within 24 hours.

3.Guarantee
Warraty period is one year or 1000hours(depends on which occurs first).It's not including the damageable spare parts of genset caused by crew wearing parts,consumable parts for daily use,human effor,neglilgence or failure of following the original maintenance manual provisons,etc.

4.Free training
We can professionally arrange experienced engineers to provide users with free training in our factory.Certainly,we also provide the paid training of customer's site.

5.Suggestion
Crew wearing parts and consumable parts for daily use is recommended to prepare more.

 

FAQ:


1. What's the power range of diesel generator?
Answer: Power range from 18-2000kw,23-2500kva.
2. What's the delivery time?
Answer: in 10 days after get the deposit.
3. What's the payment term?
Answer: we accept T/T,and 30% T/T as the deposit,the balance should be paid before delivery.
irrevocable L/C at sight.
4. What's your warranty?
Answer: 1000 working hours or 1 year whichever comes first.
5. What's your MOQ?
Answer: 1 set
6. What's the frequency of diesel generator set?
Answer: 50/60Hz
7. What's the voltage of your diesel generator set?
Answer: the voltage is 220/380V,230/400V,240/415V or as your request.

Contact Details
Weifang Best Power Equipment Co., Ltd.

Contact Person: jacky

Send your inquiry directly to us (0 / 3000)